Ericsson IBR1700 Wiring Guide for Digital Alerting | I

How to wire the Ericsson IBR1700 router for digital alerting

06/12/2026 7:13 am CDT

This article explains how to wire the Ericsson IBR1700 router to send digital alerts to HAAS Alert’s Safety Cloud.

Warning: When using a GPIO extensibility cable, DO NOT leave unused wires exposed. Cap or tape off unused wires to prevent electrical shorts or damage.

The IBR1700 can be wired using one of two methods, depending on whether ignition sensing is used and which cable is available.

Use this option only if ignition sensing is not in use.

Use this option if:

Option (Use ONE Only) Description Pin-Out
Connection (Option 1)
- Use the orange wire from the 4-pin square power port cable (Input / Pin 3).
- Connect the orange wire to the positive side of the vehicle's warning lights switch.
If the orange wire is already used for ignition sensing, Option 2 must be used.
R2R (if subscribed) will use the blue wire (Output / Pin 4).
Connection (Option 2)
- Use orange (preferred), yellow, blue, white, or green.

- Orange -> Pin 5
- Yellow -> Pin 6
- Blue -> Pin 7
- White -> Pin 8
- Green -> Pin 9
- Connect any one of these GPIO wires to the positive side of the vehicle's warning lights switch.
R2R (if subscribed) will use one of the remaining GPIO wires.